Gas Chromatography Specification

  • Power Supply
  • Electric
  • Temperature Resistance
  • Up to 450C
  • Accuracy
  • 0.01 min (retention time), 1C (temperature)
  • Shape
  • Rectangular
  • Glass Type
  • Borosilicate (for sample vials/columns)
  • Features
  • Auto-sampler, Data Logging, Programmable Temperature, Safety Lock, Auto Ignition Flame, Compact Design
  • Speed Range
  • Programmable, sample/time dependent
  • Control Type
  • Microprocessor/Software Based
  • Heating Capacity
  • Up to 450C (Oven)
  • Display Type
  • Digital LCD/LED
  • Type
  • Gas Chromatography
  • Dimension (L*W*H)
  • 540 x 540 x 370 mm (approx)
  • Equipment Type
  • Analytical Laboratory Instrument
  • Equipment Materials
  • Stainless Steel, Powder Coated Metal
  • Power
  • 230 V AC, 50/60 Hz
  • Voltage
  • 220-240 V
  • Material
  • Stainless Steel, Plastic Components
  • Application
  • Chemical, Pharmaceutical, Environmental Analysis, Forensic Laboratories, Food and Beverage Industries
  • Chromatogram Storage
  • Internal and External (USB/Computer)
  • Programming Steps
  • 16 or More Segments (Temperature Programming)
  • Detector Types
  • FID, TCD, ECD, NPD, FPD (varies by model)
  • Oven Ramp Rate
  • 10C/min to 100C/min
  • Carrier Gas
  • Hydrogen, Nitrogen, Helium (as per detector and analysis requirement)
  • Weight
  • Approx. 20-40 kg (depends on configuration)
  • Ignition System
  • Automatic
  • Noise Level
  • < 55 dB
  • Usage Environment
  • Laboratory, Controlled Environment
  • Sample Injection
  • Manual and Auto Sampler Option
  • Software
  • Compatible with Windows-based Analytical Software
  • Data Interface
  • USB, RS232, LAN (depends on model)
  • Safety Features
  • Overheat Protection, Gas Leak Detector
  • Column Compatibility
  • Capillary and Packed Columns
 

Gas Chromatography Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 10 Units Per Day
  • Delivery Time
  • 1-4 Days
  • Main Domestic Market
  • All India
 

About Gas Chromatography



Take advantage of a brilliant Price Cut on our top-tier Gas Chromatography instrument, now available to utilise with enviable offers for laboratories across India! Engineered for sublime accuracy (0.01 min retention time), this analyser offers compatibility with FID, TCD, ECD, NPD, and FPD detectors. Its design suits both capillary and packed columns, and you benefit from a digital LCD/LED interface, auto-sampler options, and comprehensive safety features. The versatile, compact rectangular form and quiet operation (<55 dB) ensure professional results for chemical, pharmaceutical, forensic, and food industries.

Special Features & Application Excellence

Our Gas Chromatography system stands out for its programmable oven (10C to 100C/min ramp), auto ignition, and internal/external data storage, providing enviable analysis flexibility. Designed for both manual and auto-sampler injections, this equipment is perfect for chemical, pharmaceutical, forensic, and environmental investigations. Its stainless steel build, digital interface, and precise temperature programming make it a sublime choice for controlled laboratory environments and demanding analytical workflows.


Payment Terms, Packaging, and Domestic Delivery

Once you place your order and confirm the asking price, your instrument will be efficiently dispatched, ensuring secure packaging with protective materials for the fragile borosilicate vials and robust equipment. Charges are competitive and transparent. Delivery covers the main domestic market within India, offering swift and reliable shipment to laboratories, research institutes, and industry suppliers across the region.


FAQ's of Gas Chromatography:


Q: How do I choose the right detector type for my application?

A: Selecting the appropriate detector (FID, TCD, ECD, NPD, or FPD) depends on the compounds you aim to analyse. Each detector excels with specific sample types, so consult your analytical requirements or speak with our technical team for guidance.

Q: What environments are ideal for utilising this gas chromatography system?

A: This equipment is designed for use in controlled laboratory settings, making it suitable for chemical, pharmaceutical, environmental, forensic, and food industry analyses.

Q: When will my Gas Chromatography order be dispatched after confirming payment?

A: Orders are typically dispatched within a specified lead time after payment confirmation, ensuring timely and secure delivery to your laboratory anywhere within India.

Q: Where can data from the instrument be stored and accessed?

A: Chromatogram data can be stored internally, on external USB devices, or transferred to computers via USB, RS232, or LAN interfaces, depending on the model.

Q: What are the main benefits of using this Gas Chromatography system?

A: Key benefits include enviable analytical accuracy, safety features like overheat and gas leak protection, flexible sample injection methods, programmable temperature control, and compatibility with Windows-based analytical software.

Q: How is sample injection managed with this system?

A: Sample injection can be conducted manually or via an auto-sampler, providing versatility and efficiency according to laboratory workflow and throughput demands.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory Instruments Category

Water Bath

Water Bath

Minimum Order Quantity : 1 Unit

Temperature Resistance : Up to 100C

Application : Laboratory heating and incubation

Power Supply : 220V / 50Hz

Dimension (L*W*H) : 300 x 250 x 110 mm

Shape : Rectangular

Lab Ultrasonicator

Lab Ultrasonicator

Minimum Order Quantity : 1 Unit

Temperature Resistance : Up to 80C

Application : Laboratory sample cleaning, degassing, emulsifying, cell disruption

Power Supply : Electric

Dimension (L*W*H) : 275 x 170 x 210 mm

Shape : Rectangular

Laminar Air Flow

Laminar Air Flow

Minimum Order Quantity : 1 Unit

Temperature Resistance : Up to 80C

Application : Laboratory, Pharmaceutical, Research, Microbiology, Industrial Clean Rooms

Power Supply : AC Supply

Dimension (L*W*H) : 3 x 2 x 2 Feet

Shape : Rectangular

Lab Flamephotometer

Lab Flamephotometer

Minimum Order Quantity : 1 Unit

Temperature Resistance : Up to 40C (Ambient)

Application : Laboratory analysis of Sodium and Potassium

Power Supply : 230V AC, 50 Hz

Dimension (L*W*H) : 340 x 260 x 170 mm

Shape : Rectangular



arrow