Titra Smart - Kafi Smart Titrator Specification

  • Features
  • Auto End Point Detection, User-programmable, Digital Display, Compact Design, Chemical Resistant
  • Temperature Resistance
  • Up to 120C
  • Shape
  • Rectangular
  • Control Type
  • Microprocessor Based
  • Glass Type
  • Borosilicate Glass
  • Display Type
  • Digital LCD Display
  • Accuracy
  • 0.1%
  • Speed Range
  • Adjustable Stirring, 100-2000 rpm
  • Power Supply
  • Electrical
  • Type
  • Automatic Titrator
  • Dimension (L*W*H)
  • 230 x 400 x 180 mm
  • Equipment Type
  • Smart Digital Titrator
  • Equipment Materials
  • Chemically Resistant Body, Glass Accessories
  • Power
  • 230V AC, 50Hz
  • Voltage
  • 230V
  • Material
  • ABS Plastic, Borosilicate Glass
  • Application
  • Laboratory Chemical Analysis, Water Testing, Food & Beverage, Pharmaceutical, Educational Institutions
  • Capacity (Ltr)
  • Up to 2 L
  • Ambient Operating Temp
  • 10-40C
  • Memory
  • Stores Up to 100 Results
  • Titration Methods
  • Acid-base, Redox, Precipitation, Complexometric
  • Display Resolution
  • 0.01 mL
  • Burette Volume
  • 10 mL / 25 mL Optional
  • Interface
  • RS232/USB for Data Export
  • Stirrer Type
  • PTFE Coated Magnetic Stirrer
  • End Point Detection
  • Electrometric (Conductometric/ Potentiometric/ Photometric modes)
  • Alarm System
  • Audio-visual end-point alert
  • Weight
  • 3.8 kg approx
  • Languages Supported
  • English
 

Titra Smart - Kafi Smart Titrator Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 10 Units Per Month
  • Delivery Time
  • 30 Days
  • Main Domestic Market
  • All India
 

About Titra Smart - Kafi Smart Titrator



Unlock unmatchable precision and savings with the Titra Smart - Kafi Smart Titrator for a limited time! Designed for unparalleled efficiency, this automatic titrator features reduced manual intervention and remarkable reliability. Choose between 10 mL or 25 mL burette volumes, with advanced end-point detection across Conductometric, Potentiometric, and Photometric modes. Experience effortless data export, robust chemical resistance, and compact design. Trust in its user-programmable functions, digital LCD display, and audio-visual end-point alerts-perfect for laboratories, water testing, food & beverage, and pharmaceutical analysis. Save now on this remarkable analytical solution.

Wide Application and Versatile Use

The Titra Smart - Kafi Smart Titrator is ideal for a diverse set of analytical tasks. Its robust, chemically resistant build makes it suitable for commercial laboratories, educational institutions, water quality analysis, food and beverage industries, and pharmaceutical testing. The device easily accommodates a wide range of titration methods-including acid-base, redox, precipitation, and complexometric-making it a versatile choice wherever precise chemical analysis is needed.


Export Markets, Sample Policy, and Dispatch Information

Our Titra Smart - Kafi Smart Titrator is in high demand in major export markets across India and internationally. We support transparent sample policies and share product samples upon proposal amount confirmation. With a highly efficient logistics team, each unit is usually dispatched within a swift delivery time after confirmation of the list price. Partnering with us ensures prompt delivery and reliable after-sales support for your analytical equipment needs.


FAQ's of Titra Smart - Kafi Smart Titrator:


Q: How does the Titra Smart - Kafi Smart Titrator benefit laboratory operations?

A: The Titra Smart provides unmatched accuracy and efficiency through automatic titration, digital data export, and rapid end-point detection. This reduces manual workload and ensures consistent results, making laboratory operations smoother.

Q: What titration methods are supported by this device?

A: It accommodates acid-base, redox, precipitation, and complexometric titration methods, delivering flexibility for a wide array of chemical analyses in laboratories and industry settings.

Q: Where can the Titra Smart - Kafi Smart Titrator be used?

A: This titrator is suitable for use in commercial labs, educational institutions, water and food testing environments, and the pharmaceutical sector, thanks to its chemically resistant design and versatility.

Q: When will my Titra Smart device be dispatched after placing an order?

A: After finalizing the proposal amount and payment of the list price, orders are typically dispatched within a brief delivery timeframe, ensuring timely receipt.

Q: What is the process for exporting the Titra Smart Titrator internationally?

A: Upon inquiry, a formal export proposal, including list price and sample policy, will be shared. Once the order is confirmed, the product is efficiently dispatched to international destinations.

Q: How accurate is the Titra Smart and what memory capacity does it offer?

A: The titrator achieves remarkable accuracy of 0.1% and can store up to 100 result entries, ensuring both precision and dependable record-keeping for your analyses.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Titrator And Karl Fischer Titrator Category

Titra - Kafi Fischer Titrator

Titra - Kafi Fischer Titrator

Minimum Order Quantity : 1 Unit

Glass Type : Borosilicate Glass

Control Type : Microprocessorbased control

Voltage : 220 V AC

Power : 40 W

Equipment Type : Automatic Titrator



arrow